Availability: | |
---|---|
Quantity: | |
SP-520A
SP
8543709990
For ultrasonic components measuring instrument, the most important is the admittance chart, logarithmic graph of the two graphics (the two graphics is the main method of qualified qualified), and more than a dozen parameters: resonance frequency Fs, the maximum conductance Gmax, bandwidth F2-F1, anti-resonance frequency Fp, quality factor Qm, free capacitance CT, dynamic resistance R1, dynamic inductance L1, dynamic capacitance C1, static capacitance C0, effective electromechanical coupling coefficient Keff.
The Measuring instrument which can easily replace much more complex and more complicated, also many times more expensive instruments from Agilent/HP, as for instance: HP Impedance Gain-Phase Analyzer 4294A, Agilent E5100A, Network Analyzer, HP 3563A,Control System Analyzer etc. It is also very easy to use SP-PV520A (by engineers or ordinary production workers).
Functions moldel | SP520A-S | SP520A-T | SP520A-V |
Characteristics | Portable,Full-screen touch screen,7.8 inch screen | ||
Size | L 240 mm;W 190mm;Front height 50mm;Back height 100mm | ||
Frequency range | 1KHZ-1MHZ | 1-3MHZ | 1-5MHZ |
Measurement | All parametric graphs | ||
Basic accuracy | <0.1% | ||
Measuring speed | 5 seconds per piece(1200 point scan) | ||
Frequency accuracy | ±10ppm | ||
Phase Accuracy | 0.15 degrees | ||
Ambient temperature | 10-40ºC | ||
Impedance range | 1Ω-1MΩ | ||
Stepped frequency | 0.1Hz to Any | ||
Power supply | AC100V-AC250V,50-60Hz |
Resonant frequency:Fs
Antiresonant frequency:Fp
Static capacitor:C0
Dynamic impedance:R1
Dynamic capacitance: C1
Dynamic inductance: L1
Free Capacitance: CT
Free dielectric constant
Mechanical Quality Factor:Qm
Electromechanical coupling coefficient:Keff
Planar electromechanical coupling coefficient: Kp
Half power point:F1 and F2
The impedance analyzer is mainly applicable to the measurement of impedance characteristics of various ultrasonic devices, including piezoelectric ceramics, transducers, ultrasonic cleaning machines, ultrasonic plastic welding machines, hydroacoustics, magnetostrictive materials, ultrasonic pulverizers, ultrasonic atomization, ultrasonic tooth cleaning, ultrasonic ranging, phacoemulsification, ultrasonic descaling, ultrasonic motors, etc.
1. Practicality and ease of use. No need for ultrasonic expertise.
2. Allows the quality control of ultrasonic transducers reducing technical assistance.
3. Makes fast and accurate manufacturing of sonotrodes possible.
4. Affordable cost.
5. Reduces ultrasonic equipment maintenance costs because it allows preventive maintenance.
For ultrasonic components measuring instrument, the most important is the admittance chart, logarithmic graph of the two graphics (the two graphics is the main method of qualified qualified), and more than a dozen parameters: resonance frequency Fs, the maximum conductance Gmax, bandwidth F2-F1, anti-resonance frequency Fp, quality factor Qm, free capacitance CT, dynamic resistance R1, dynamic inductance L1, dynamic capacitance C1, static capacitance C0, effective electromechanical coupling coefficient Keff.
The Measuring instrument which can easily replace much more complex and more complicated, also many times more expensive instruments from Agilent/HP, as for instance: HP Impedance Gain-Phase Analyzer 4294A, Agilent E5100A, Network Analyzer, HP 3563A,Control System Analyzer etc. It is also very easy to use SP-PV520A (by engineers or ordinary production workers).
Functions moldel | SP520A-S | SP520A-T | SP520A-V |
Characteristics | Portable,Full-screen touch screen,7.8 inch screen | ||
Size | L 240 mm;W 190mm;Front height 50mm;Back height 100mm | ||
Frequency range | 1KHZ-1MHZ | 1-3MHZ | 1-5MHZ |
Measurement | All parametric graphs | ||
Basic accuracy | <0.1% | ||
Measuring speed | 5 seconds per piece(1200 point scan) | ||
Frequency accuracy | ±10ppm | ||
Phase Accuracy | 0.15 degrees | ||
Ambient temperature | 10-40ºC | ||
Impedance range | 1Ω-1MΩ | ||
Stepped frequency | 0.1Hz to Any | ||
Power supply | AC100V-AC250V,50-60Hz |
Resonant frequency:Fs
Antiresonant frequency:Fp
Static capacitor:C0
Dynamic impedance:R1
Dynamic capacitance: C1
Dynamic inductance: L1
Free Capacitance: CT
Free dielectric constant
Mechanical Quality Factor:Qm
Electromechanical coupling coefficient:Keff
Planar electromechanical coupling coefficient: Kp
Half power point:F1 and F2
The impedance analyzer is mainly applicable to the measurement of impedance characteristics of various ultrasonic devices, including piezoelectric ceramics, transducers, ultrasonic cleaning machines, ultrasonic plastic welding machines, hydroacoustics, magnetostrictive materials, ultrasonic pulverizers, ultrasonic atomization, ultrasonic tooth cleaning, ultrasonic ranging, phacoemulsification, ultrasonic descaling, ultrasonic motors, etc.
1. Practicality and ease of use. No need for ultrasonic expertise.
2. Allows the quality control of ultrasonic transducers reducing technical assistance.
3. Makes fast and accurate manufacturing of sonotrodes possible.
4. Affordable cost.
5. Reduces ultrasonic equipment maintenance costs because it allows preventive maintenance.
Address: No.30 DATANG VILLAGE FUYANG DISTRICT HANGZHOU CITY ZHEJIANG PROVINCE CHINA
Email: info@shengpaigroup.com
Tel: 0086-571-63127797
Mobile: 0086-15888033040
0086-15355441892
NEWSLETTER
Signup to be the first to know about discounts and new product releases.